Split type flue oxygen analyzer

Split type flue oxygen analyzer

    Split type flue oxygen analyzer has a friendly communication menu that makes the operation visual and simple. The measured accuracy of the whole measurement range can be met by single-point calibration. it adopts imported new type zirconia sensor with relatively rare error.

Split type flue oxygen analyzer can be widely applied in department of electronic power, metallurgy, heating, building material and electron, etc to analyze the oxygen content in flue gas from industrial boiler and furnace. It can also be used in monitoring and analyzing the oxygen concentration in the combustion gas from large or small-scale boiler, industrial boiler and combustion devices to achieve the purposes of reasonable combustion for low oxygen content, lowering the combustion consumption and loss, stabilizing techniques, improving the products quality and reducing environment pollution, etc.

Split type flue oxygen analyzer main features:

1. The auto-compensation system for temperature with high accuracy could eliminate the influence from environment temperature.

2. The measurement range can be expanded to 0 ~ 40.00%O2 (oxygen-enriched combustion) with the measurement range shifting automatically;

3. Users can set the upper and lower limits of oxygen concentration corresponding to 4-20mA output to get the analog output with higher accuracy;

4. One-way or two-way communication with the computer can be accomplished through the communication port;

5. The advanced calibration function allow users to calibrate online.

Split type flue oxygen analyzer technical parameters:

Test principle

zirconia

Display mode

4 bits LED display

Test range

0 ~ 10/25.00% O2

Expanded range

0 ~ 10/25/40.00% O2 (oxygen-enriched combustion)

Resolution

0.01%

Accuracy

≤±1.5%FS

Repeatability

≤±1%

Response time

T90≤30S

Analog output

4~20mA.DC(non-isolated output, loaded resistance lower than 500 Ohm) 

0~5V.DC(non-isolated output, loaded resistance higher than 10k Ohm) 

1 way programmable alarm output (Dry contact type, maximum load 220VAC/2A)  

Communication Port

RS232 (default) or RS485

Calibration mode

online   one-point calibration

Power supply

AC220V±10% 50/60Hz

Operation temperature

Gauge: -10 ~ +50℃

Probe: low-temperature type,0 ~ 350

mid-temperature type,0 ~ 700

Install Hole Cut

Φ50mm ~ Φ90mm

Connection way

Cable (8 meters for standard equipment)

The length of the probe

1 meter in usual (other length customizable)

Serving life

>3 years (under normal use)

Install mode

inserting mount and DN65 standard flange for the probe,wall mount for the gauge

Disclaimer: The product introduction content (including product images, product descriptions, technical parameters, etc.) of this site is for reference only. As the update may not be timely, there will be some differences between the content and the actual situation. Please contact our sales staff to confirm. The information provided on this site does not constitute any offer or promise, and the company will improve and modify any information on the website from time to time without prior notice.

Contact Us
  • E-mail: cysi@cysi.wang
  • Tel: +86 371 5519 9322
  • Fax: +86 371 8603 6875
  • Add: No. 820, 8th Floor, 1st Unit, 9th Block, Cuizhu Street, High-Tech Zone, Zhengzhou, Henan, China




Follow Us

Copyright © Zhengzhou CY Scientific Instrument Co., Ltd. All Rights Reserved    Update cookies preferences

| Sitemap |       Technical Support: